- Home
-
Shop
- Assistive Devices
- Cerumen Management
- Clinical Tools & Supplies
-
Diagnostic Equipment & Supplies
Diagnostic Equipment & Supplies
- ABR & OAE Systems
- Air, Bone & Insert Earphones
- Audiograms & Forms
- Audiometers
- Auditory Test Recordings
- Balance Supplies
- Electrodes & Supplies
- Hearing Instrument Programming & Test Box
- Infant Screening Supplies
- Recording Paper
- REM Systems & Probe Tubes
- Tympanometers, Printers & Parts
- Tuning Forks
- Misc Parts & Supplies
- VRA & E-CPA
- Eartips
- Fitting Supplies
- Hearing Conservation
- Impression Materials
- Infection Control
- Mobile Audiology
- Office & Educational Items
- Otoscopes & Headlamps
- Resale Accessories
- Specials
- EQUIPMENT
- Request
- Resources
- MEDIA
- About
- Home>
- Catalog>
- Diagnostic Equipment & Supplies>
- Tympanometers, Printers & Parts>
- Tympanometers>
- Resonance R36M-PT Clinical Middle Ear Analyzer w / Multifrequency Probe
Resonance R36M-PT Clinical Middle Ear Analyzer w / Multifrequency Probe
Product Code: R36M-PT
- Clinical, multi-frequency tympanometer with ipsi & contra acoustic reflex/decay capabilities and other special tests
- 226Hz 678 Hz, 800 Hz and 1000 Hz probe tones (pressure range +200 daPa to -400 daPa)
- Animation feature for children when using 1000 Hz probe tone
- Ipsi & contra acoustic reflex & decay testing capabilities at 0.5 1, 2 & 4 kHz (intensity range 50-110 dBHL)
- Special tests
- Eustachian Tube Function (ETF) tests
- Acoustic Reflex Latency Test (ARLT)
- Growth-DLI and non-acoustic
- 7" LCD, color graphic display
- Powered by mains AC/DC adapter (included) that plugs into standard wall outlet
- MDS software (included) allows data transfer to PC via Bluetooth 2.1 or USB cable, data storage (locally or in Noah) and reporting/printing features (NOTE: built-in printer within r26m-PT is obsolete)
- Three year warranty
- multi-frequency tympanometer with ipsi/contra acoustic reflex/decay and no special tests: item# r26m-PT
- optional external printer: item# O1000094
- Product Docs
- Parts & Accessories
- Controls & Components
- Special Tests
- Printing/PDF Reports
- Before You Buy
- Software
Front Panel Controls & Components
1. display screen
2. built-in thermal printer (obsolete)
3. knob for manual pressure adjustment & main menu navigation
4. F1 - F6 function keys: enables execution of function displayed on the bottom section of the screen
5. TEST: when in test mode, this key enables return to main menu
6. ENTER: key for accessing tests from main menu
7. ARROW KEYS: used to select function on main menu
8. SIGNAL: manual start of reflex test
9. FREQUENCY
10. IPSI
11. CONTRA
12. SIDE: (right or left ear)
13. START/STOP
14. PRINT
Back Panel Components
15. CONTRA transducer jack
16. PROBE connection
17. PRESSURE connector
18. FOOT SWITCH (obsolete)
19. USB host port connection
20. USB slave port connection for PC communication and data transfer
21. ON/OFF
ETF for intact and perforated tympanic membrane
- Select ETF test from main menu
- If autorun function is active, the tests will start automatically; otherwise, press START
- After first tympanogram completed, instruct patient to swallow
- Press CONTINUE to perform second tympanometer
- After second tympanogram completed, instruct patient to swallow.
- Press CONTINUE
Non-acoustic
Test with graphical representation similar to the Decay test. Test length can be either of 10 or 20 secs. The test is conducted without acoustic stimulation, therefore the stapedial reflex can be stimulated by a tactile or ocular contraction with light air blows. This test can be adopted to investigate subjects with Patulous Eustachian Tube. To change the length of the test press F5. The test can be conducted at 0 daPa or at tymp peak (maximum mobility) performing a tympanogram by pressing F1 PEAK (Zero or Auto).
Quick tests
Three rapid execution tests can be selected from the test selection page: Quick check, Quick screening, Quick decay. All three tests include the execution of a tympanogram and subsequently tests for the detection of the stapedial reflex performed at the pressure at which the peak has been detected during the tympanogram . For all tests the various execution parameters can be changed by pressing F6 > F5. In the Quick check the stimuli for the reflexes will be emitted at the intensity selected in the parameters window, in the Quick Screening a reflex threshold research will be carried out with successive stimulations with increasing intensity, the Quick decay will be performed using the same method of the screening plus the decay test. The “ Children” mode can be activated in Quick Check by pressing F5. This feature, designed for use with children, displays a sequence of colored images on the screen that are meant to attract the child’s attention while performing the examination. When the image sequence is running, the test will be run in background, giving the operator the necessary information.
Growth - DLI
Similar to the Decay test, once the stimulus is issued at a fixed intensity, a series of short increment stimuli at variable intensity can be sent to the subject in order to highlight a further contraction of the stapedius. All controls are similar to those seen in the previous test for reflex detection.
HF tympanometry
Similar in execution and controls to the 226 Hz Tympanometry; three separate graphic areas are available to perform three different tympanograms at different probe tone frequencies: 678 Hz, 800 Hz and 10000 Hz. The three tympanograms can be run with pressure generation in automatic or in manual mode. For each tympanogram, at the end of the test, three curves will be displayed shown. In tympanometry with 1000 Hz tone, the CHILDREN mode is available, as described in the Quick check.
How do I add my logo to the report?
- go to MENU
- select TOOLS
- REPORT OPTIONS
- REPORT CUSTOMIZATION
- click the BUSINESS INFO tab.
- right click on image place holder to LOAD logo
Things to Know Before you Buy
The built-in printer feature is obsolete and no longer functional
At the end of 2021, the printer was discontinued and Resonance was unable to find a comparable replacement that would fit in the unit. Rather than redesigning the r36M form factor, the built-in printer comportment remains on current units.
The unit does come packaged with free MDS software that allows data transfer from the audiometer to your PC for data management and report generation. The transferred data can be printed off from your PC. This represents the most common way providers print data from this unit. Another option for printing data from the unit is to purchase a compatible external printer that connects directly to the unit.
Technical support, calibration, and service is provided and managed through Oaktree Products
Responsive, efficient, and effective support is critical for busy providers to be able to use their equipment without delay. Equipment calibration is required annually. Equipment may need to be serviced over the years. Oaktree Products has made arrangements to coordinate and provide support, calibration and service to allow providers to focus on their clinical practice.
NOTE:
- see PRODUCT DOCUMENTS tab and click SOFTWARE MANUAL to download MDS User Manual
- QUICK START and QUICK START NOAH instructions outlined below after INSTALLATION
Minimal Requirements for PC to work with MDS Software:
- Windows XP
- Windows Vista
- Windows 7
- Windows 8
Minimal Requirements for Noah to work with MDS Software:
- Noah version 4.X.
Resonance MDS Software & License Key:
The Resonance MDS Software is included free of charge with this Resonance unit. The software allows creation and management of a patient database on your PC and the ability to transfer patient information and test results from your Resonance unit to your PC. As a software program, a license key will be required to permanently activate the MDS software. The license key can be found within the Resonance License PDF file that resides in the MDS Suite folder on the USB thumb drive packaged with your unit. Print or refer to this file when your unit generates a prompt for MDS License Key Activation.
MDS License Key Activation:
The MDS software file resides in the MDS folder on the USB thumb drive packaged with your unit. The software is located on the USB thumb drive packaged with the unit. Go to the MDS Suite folder, click MDS Setup and follow installation instructions. Be sure to click "Create Shortcut to Desktop" when prompted to have the software icon appear on your desktop for easiest access. NOTE: MDS software will accommodate data from five patients without requiring a software license activation key. When trying to add data from the sixth patient, the following Licensure Key activation window will appear:
This means the demo version of the MDS software has expired and it will be necessary to enter the License Key associated with your specific unit. The MDS License Key is listed in the PDF file called Resonance License located within the MDS folder on the USB thumb drive that came packaged with the unit. If you are unable to find the PDF file, contact Oaktree Products with the make/model and serial number of your unit. We will make arrangements for the vendor to issue the necessary MDS License Key.
Cables for Connection with PC:
The Resonance device can be connected to a PC using a USB cable (included)
INSTALLATION:
- Insert USB drive to PC
- Double click file "MRS Resonance Setup.exe" to begin install
- select YES if prompted with "Do you want to allow the following program from an unknown publisher make changes to your computer?"
- Select language for installation from provided choices
- At the Welcome screen, to continue, select NEXT
- When prompted "Would you like to install this device software?", check the box next to "Always trust software from MRS Srl", then click INSTALL
- When installation complete, select either "Run MRS Resonance Now" to run the program immediately, or click FINISH to complete installation and exit the program
- The icon of the program will now be present on the PC desktop and in the program bar called MRS Resonance
Quick Start Instructions:
- launch program
- at the authentication window, "admin" will populate as UserName
- type "a" (lower case letter a) as the password (password can be changed later)
- check the box "remember me" to no longer have the authentication window populate when launching program
- click SESSIONS (upper horizontal menu bar)
To Create a New Patient:
- click NEW (from upper horizontal menu bar)
- fill the the following MANDATORY FIELDS
- First Name
- Surname
- Birth Date
- Birth Place
- Choose Gender
- click PRIVACY ACCEPTED
- click SAVE to create patient
- click EDIT (to proceed with transferring data from Resonance device to your PC)
Transferring data from Resonance unit to PC:
- after creating NEW patient, the icon "Acquire data from device" will be active
- conduct test on the Resonance unit
- connect Resonance device to the PC where MDS is running
- click on "Acquire data from device"
- an "Acquisition" or "Acquisizione" window will appear
- select the Resonance device from pull down menu appearing under destination patient name
- click DOWNLOAD
- once the system indicates "Acquired Data", click SAVE & EXIT button to store data in database
View transferred test data:
Once data is transferred from a Resonance unit to a PC and saved, the test data will not reside in the '"Patient Historic Sessions" area located in lower left hand portion of the screen. To view the transferred data:
- select SESSIONS tab located in the lower right hand portion of the screen under the image of the patient silhouette
- in the TESTS IN SELECTION SESSION, click VIEW TEST DETAIL
QUICK START NOAH:
- launch MDS
- click icon in the left upper corner of main window
- select TOOLS > Noah > Register Module (this procedure executed one time only)
- close Resonance software suite and run Noah
- once Noah opened, a RESONANCE button will appear in the upper horizontal menu
- to transfer data, follow instructions outlined above QUICK START INSTRUCTIONS, and select a patient in the Noah database
- click RESONANCE button to run MDS
- MDS will initiate; when the "Acquisition" or "Acquisizione" window appears, click DOWNLOAD to transfer data to Noah database