Primus Pro PC-Based Two-Channel Audiometer with DD45 Headphones
Double-tap and hold to zoom.
Mouse over the image to zoom.

Primus Pro PC-Based Two-Channel Audiometer with DD45 Headphones

Product Code: PRIMUSPRO

  • PC-based, portable, two-channel audiometer with air, bone, speech capabilities with module architecture to grow with the needs of your practice   
    • PC requirements    
      • Operating system:  Windows 8.1, 10, 10 Anniversary update, & 11
      • Required connections: CD Drive 9if using CDs for speech testing) or USB 2.0 connection
      • CPU: 2 GHz processor with 2 GB System RAM (4GB or more)
      • Hard disk space: 2 GB free for software
    • Air conduction            
      • frequency range: 125 Hz to 8000 Hz
      • attenuation levels: -10 dBHL to 120 dBHL (step size 5 dB, 2 dB, 1 dB)
      • packaged with calibrated DD45 audiometric headphones
      • includes patient response button
      • talk-forward capabilities (operator headset with microphone included)
      • talk-back capabilities (talk-back microphone included)
      • manual and auto testing capabilities
    • Bone conduction           
      • frequency range: 250 Hz to 8000 Hz
      • attenuation levels: -10 dBHL to 80 dBHL (step size 5 dB, 2 dB, 1 dB)
      • packaged with calibrated B71 vibrator
      • manual and auto testing capabilities
    • Speech audiometry  
      • Monitored-live voice capabilities
      • Recorded speech testing by external CD with USB 2.0 connection (not included), or sound library
    • Special Features 
      • Workflow feature allows clinics to customize test batteries (e.g. new patient or extended frequency audiometry) according to clinical standards or established guidelines/best practices
      • Nudging feature navigates providers through established workflows while offering the provider the flexibility to override nudging prompts when circumstances require deviation from protocols
      • ability to add the following capabilities as needed:
        • high frequency audiometry (16 kHz)
        • REM System with speech mapping
  • Powered by AC/DC adapter (included) that plugs into standard wall outlet and USB cable (included) 
  • Noah compatible
  • Three year warranty
This Kit Contains:
  • Auditdata Audiometry Software Module (x 1)
  • Auditdata Primus Bone Conductor - B71 (x 1)
  • Auditdata Primus DD45 w. HBA Headband (x 1)
  • Auditdata Primus Pro Fitting Unit (x 1)
  • Auditdata Primus Microphone (Talk Back) (x 1)
  • Auditdata Primus Headset w / Mic. -S (Talk Over) (x 1)

 

 

 

  • Primus Pro Audiometer Only
  • DD45 Headphones
  • B71 Bone Vibrator
  • Patient Response Button
  • Patient Microphone (talkback)
  • Operator Headset with Microphone
  • USB Stick with Software

Pure Tone Audiometry

How to open the module, utilize toolbar, operate the audiometer, communicate with patient, settings and configuration

 

How to perform audiometry

 

How to perform automated audiometry

 

How to add/remove frequencies used for automated audiometry

 

 

How to edit pure tone audiometry parameters

 

 

Speech Audiometry

How to operate the Primus speech audiometer

 

Speech detection threshold testing

 

 

Editing speech audiometry parameters

 

 

Uploading speech materials into Primus (stand alone)

 

Performing SRT in Primus

 

Performing Quick SIN in Primus

What does "modular architecture" mean?

The Primus Pro is supported by software that can be customized to the provider's needs; a portfolio of available software modules (e.g. audiometry, REM, speech mapping, video otoscopy) allows the provider to only buy what they need and to expand the Primus Pro audiometer with time, when the need comes. For example, the Primus Pro (item# primuspro) can be upgraded to include REM capabilities at a later date. 

How do I install Primus on my PC?

 

 

How do I navigate Primus software?

 

 

What is the workflow feature?

The Primus software provides the flexibility for clinics to create workflows to ensure everyone provides the same testing procedure, follows the same processes, and delivers the same quality service. For example, an "ototoxicity workflow" can make sure providers collect extended high frequency thresholds at 10, 12.5 and 16 kHz.  A "new hearing aid fitting workflow" may be implemented to ensure speech mapping is conducted to validate the fitting. Workflows can also be used for onboarding newly hired providers or students to assist with offering consistent and quality care for every patient. Workflows assist in controlling standard of care, enhancing patient outcomes, improving quality of care, help with compliance, and identify processes that may require improvement. 

How do I create/add workflows in Primus?

 

 

How do I access and use workflows in Primus?

 

 

What is the nudging feature?

The nudging feature manifests as a friendly reminder or notification, aimed to help providers adhere to best practices and follow clinical protocols. During testing and fitting, a small notification can be configured to populate, "nudging the provider to take proper action. For example, two common configurable reminders include testing inter-octave frequencies and the need for masking. The functionality is fully configurable by the user or administrator of the system.

How do I remove a workflow from Primus?  

 

How do I upload speech materials into my Primus?

 

 

Things to Know Before you Buy

Technical support, calibration, and service is provided and managed through Oaktree Products

Responsive, efficient, and effective support is critical for busy providers to be able to use their equipment without delay. Equipment calibration is required annually. Equipment may need to be serviced over the years.  Oaktree Products has made arrangements to coordinate and provide support, calibration and service to allow providers to focus on their clinical practice.

Module Not Licensed Error Message

Your Primus Ice should come packaged with a License Code Certificate.  To add it to the Primus System, go the HELP (menu at the top) > LICENSE INFORMATION > ENTER CODE. 

If you do not have a License Code Certificate, Contact Oaktree Products at 800.347.1960 or otp@oaktreeproducts.com with the following information:

  • Oaktree account number and/or name of practice
  • Make & model of Primus System (e.g. Primus Ice, Primus Pro, Primus Pro-HF, Primus Pro-REM, Primus Pro-Combo)
  • Serial number of unit

This information is needed for Oaktree to quickly resolve the issue.  Oaktree will reissue a license code to you.